Fluke 729 300G FC Pressure Calibrator, 300 PSI, 20 Bar, 24V Loop Power is a product engineered with precision, delivering exceptional performance
with features like automatic pressure generation and regulation to 300 psi, easily document the process using onboard test templates and automatic internal finepressure adjustment.
Maintive brings to you 100% genuine Pressure Calibrators from Fluke at your doorstep with fast shipping, multiple and secure payment methods and easy returns. Order 729 300G FC Pressure Calibrator, 300 PSI, 20 Bar, 24V Loop Power today at the best price only from Maintive.
Features
Automatic pressure generation and regulation to 300 psi
Easily document the process using onboard test templates
Automatic internal fine-pressure adjustment
Measure, source and simulate 4 to 20 mA signals
Troubleshoot and calibrate HART smart transmitters
Items Included
Calibrator with Wireless
Communication
Soft Case
Stackable Test Leads
AC280 Hook Clips
Alligator Clips
Test Probes
Magnetic Hanger Kit
Carrying Strap
Wireless Adapter
Quick Start Guide
Safety Sheet
Power Supply
Rechargeable Battery (installed)
Hose Kit with PUsh Fit Adapters
Hanging Clip
USB Cable
1/8 in FNPT to 1/4 in FNPT Adapter
1/8 in FNPT to F-M20 Adapter
1/8 in FNPT to 1/4 in FBSP Adapter
PTFE Tape
2x Sintered Filters
Water Trap Drain
Valve Tuning Hoses
Specifications
PSI range, resolution-12.000 to 300.000 psi
Bar range, resolution-0.8273 to 20.6843 bar
kPa range, resolution-82.73 to 2068.43 kPa
Current Measurement0 to 24mA
Voltage Measurement0 to 30V
Accuracy0.01% ±2 LSD all ranges (at 23 °C ±5 °C)
Loop compliance voltage24 V dc @ 20 mA
Temperature measurement only/100 Ω Pt(385) RTD-50 °C to 150 °C (-58 °F to 302 °F)
Drive capability1200 Ω without HART resistor, 950 Ω with internal HART resistor
Size (HxWxL)7 x 27.94 x 17.27 cm (2.75 x 11 x 6.8 in)
Warranty3 years manufacturer's warranty
PSI range, resolution-12.000 to 300.000 psi
Bar range, resolution-0.8273 to 20.6843 bar
kPa range, resolution-82.73 to 2068.43 kPa
Current Measurement0 to 24mA
Voltage Measurement0 to 30V
Accuracy0.01% ±2 LSD all ranges (at 23 °C ±5 °C)
Loop compliance voltage24 V dc @ 20 mA
Temperature measurement only/100 Ω Pt(385) RTD-50 °C to 150 °C (-58 °F to 302 °F)
Drive capability1200 Ω without HART resistor, 950 Ω with internal HART resistor
Size (HxWxL)7 x 27.94 x 17.27 cm (2.75 x 11 x 6.8 in)
Warranty3 years manufacturer's warranty